{"id":1436,"date":"2024-10-08T13:01:43","date_gmt":"2024-10-08T18:01:43","guid":{"rendered":"http:\/\/climaticdesign.net\/?page_id=1436"},"modified":"2024-11-08T11:35:59","modified_gmt":"2024-11-08T16:35:59","slug":"the-afro-archives-at-the-upton-mansion","status":"publish","type":"page","link":"https:\/\/climaticdesign.net\/?page_id=1436","title":{"rendered":"The AFRO Archives at the Upton Mansion"},"content":{"rendered":"\n<p><strong>Project Location:&nbsp;<\/strong> 811 W. Lanvale Street, Baltimore, Maryland<br><strong>Owner: <\/strong>AFRO Charities<strong>&nbsp;<\/strong><br><strong>Rating system<\/strong>:&nbsp;LEED v4 BD+C: NC<br><strong>Gross floor area:<\/strong> 17,394 GSF<br><strong>Project type:<\/strong> Office: Other Office<br><strong>Anticipated end date:<\/strong> 30 Jun 2024<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-64.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"551\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-64.png\" alt=\"\" class=\"wp-image-1830\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-64.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-64-300x170.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-64-768x434.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Exterior looking at new addition &#8211; courtesy of Ziger Snead Architects<\/sup><\/figcaption><\/figure>\n\n\n\n<p>Climatic Design LLC is working with the design team from the beginning of the design phases to provide early analysis of energy systems of the project in order to identify synergies within the project design that can optimize energy performances of this historic project. Simulation results of the latest energy models demonstrated that annual energy costs of the proposed design is 34.8% lower than the reference ASHRAE 90.1-2010 model. This indicates the project not only meets Minimum Energy Performance requirement but also qualifies for thirteen (13) Optimize Energy Performance points under LEED v4 BD+C: NC rating system.<\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full is-resized\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-20.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"665\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-20.png\" alt=\"\" class=\"wp-image-1442\" style=\"width:523px;height:auto\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-20.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-20-300x205.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-20-768x524.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model, East view<\/sup><\/figcaption><\/figure><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full is-resized\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-17.png\"><img loading=\"lazy\" decoding=\"async\" width=\"687\" height=\"530\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-17.png\" alt=\"\" class=\"wp-image-1438\" style=\"width:539px;height:auto\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-17.png 687w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-17-300x231.png 300w\" sizes=\"(max-width: 687px) 100vw, 687px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model, North West view<\/sup><\/figcaption><\/figure><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full is-resized\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-18.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"641\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-18.png\" alt=\"\" class=\"wp-image-1439\" style=\"width:541px;height:auto\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-18.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-18-300x197.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-18-768x505.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model Demonstrating different glazing types<\/sup><\/figcaption><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-62.png\"><img loading=\"lazy\" decoding=\"async\" width=\"686\" height=\"637\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-62.png\" alt=\"\" class=\"wp-image-1826\" style=\"width:870px;height:auto\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-62.png 686w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-62-300x279.png 300w\" sizes=\"(max-width: 686px) 100vw, 686px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Annual Energy Consumption by Endues &#8211; Proposed Design vs Baseline Case<\/sup><\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-63.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"729\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-63.png\" alt=\"\" class=\"wp-image-1827\" style=\"width:877px;height:auto\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-63.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-63-300x224.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-63-768x574.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Project Location:&nbsp; 811 W. Lanvale Street, Baltimore, MarylandOwner: AFRO Charities&nbsp;Rating system:&nbsp;LEED v4 BD+C: NCGross floor area: 17,394 GSFProject type: Office: Other OfficeAnticipated end date: 30 Jun 2024 Climatic Design LLC is working with the design team from the beginning of the design phases to provide early analysis of energy systems of the project in order [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1436","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1436"}],"collection":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1436"}],"version-history":[{"count":12,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1436\/revisions"}],"predecessor-version":[{"id":1831,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1436\/revisions\/1831"}],"wp:attachment":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1436"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}