{"id":1448,"date":"2024-10-08T14:18:31","date_gmt":"2024-10-08T19:18:31","guid":{"rendered":"http:\/\/climaticdesign.net\/?page_id=1448"},"modified":"2024-11-01T13:30:29","modified_gmt":"2024-11-01T18:30:29","slug":"maryland-school-for-the-deaf-veditz-building","status":"publish","type":"page","link":"https:\/\/climaticdesign.net\/?page_id=1448","title":{"rendered":"Maryland School for the Deaf &#8211; Veditz Building"},"content":{"rendered":"\n<p><strong>Project Location:&nbsp;<\/strong>101 Clarke Pl, Frederick, Maryland<br><strong>Owner:&nbsp;<\/strong>Department of General Services<br><strong>Architectural Firm:&nbsp;<\/strong>Quinn Evans, Baltimore, Maryland<br><strong>Rating system:&nbsp;<\/strong> LEED v4 ID+C: CI<br><strong>Gross floor area:<\/strong> 49,277 GSF<br><strong>Project type:<\/strong> Office: Administrative\/Professional<br><strong>Anticipated end date<\/strong>: 30 Jun 2023<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-21.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"608\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-21.png\" alt=\"\" class=\"wp-image-1449\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-21.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-21-300x187.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-21-768x479.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>MSD Veditz Building aerial view \u2013 Schematic Design, courtesy of Quinn Vans Architects<\/sup><\/figcaption><\/figure><\/div>\n\n\n<p>Climatic Design, LLC (CDL) has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for the MSD Veditz Building. Based on the final simulation results, the proposed design not only meets Minimum Energy Performance requirement but also qualifies for additional LEED points. Simulation results of the final energy models as shown in the Total energy usage table of the Performance Output tab of the Minimum Energy Performance Calculator, indicates the proposed design is 29.9% more energy cost efficient than the ASHRAE 90.1-2010 reference model. In the Design Final Review the project was awarded twenty five (25) points for Optimize Energy Performance credit (EA904).<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-2.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"421\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-2.png\" alt=\"\" class=\"wp-image-1673\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-2.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-2-300x130.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-2-768x332.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model demonstrating different glazing types, North East view<\/sup><\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-4.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"382\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-4.png\" alt=\"\" class=\"wp-image-1675\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-4.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-4-300x118.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-4-768x301.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model, South East view<\/sup><\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-22.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"445\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-22.png\" alt=\"\" class=\"wp-image-1450\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-22.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-22-300x137.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-22-768x351.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model with the original \u201cAs Is\u201d orientation, South West view<\/sup><\/figcaption><\/figure>\n\n\n\n<p> <\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-3.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"418\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-3.png\" alt=\"\" class=\"wp-image-1674\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-3.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-3-300x129.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-3-768x329.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Proposed Model demonstrating different glazing types, Aerial view from North West<\/sup><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-5.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"179\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-5.png\" alt=\"\" class=\"wp-image-1676\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-5.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-5-300x55.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-5-768x141.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Source: Performance Output tab of the Minimum Energy Performance Calculator \u2013 LEED-Online<\/sup><\/figcaption><\/figure>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-63.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"1003\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-63.png\" alt=\"\" class=\"wp-image-1537\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-63.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-63-292x300.png 292w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-63-768x790.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><\/figure><\/div>","protected":false},"excerpt":{"rendered":"<p>Project Location:&nbsp;101 Clarke Pl, Frederick, MarylandOwner:&nbsp;Department of General ServicesArchitectural Firm:&nbsp;Quinn Evans, Baltimore, MarylandRating system:&nbsp; LEED v4 ID+C: CIGross floor area: 49,277 GSFProject type: Office: Administrative\/ProfessionalAnticipated end date: 30 Jun 2023 Climatic Design, LLC (CDL) has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1448","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1448"}],"collection":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1448"}],"version-history":[{"count":5,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1448\/revisions"}],"predecessor-version":[{"id":1677,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1448\/revisions\/1677"}],"wp:attachment":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1448"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}