{"id":1458,"date":"2024-10-08T14:57:03","date_gmt":"2024-10-08T19:57:03","guid":{"rendered":"http:\/\/climaticdesign.net\/?page_id=1458"},"modified":"2024-11-01T15:08:29","modified_gmt":"2024-11-01T20:08:29","slug":"pompeian-tpa-warehouse","status":"publish","type":"page","link":"https:\/\/climaticdesign.net\/?page_id=1458","title":{"rendered":"Pompeian TPA Warehouse"},"content":{"rendered":"\n<p><strong>Project Location:&nbsp;<\/strong>2100 Sparrows Point Road, Edgemere, Maryland<br><strong>Owner:&nbsp;<\/strong>Tradepoint Atlantic LLC<br><strong>Architectural Firm:&nbsp;<\/strong>Hofmann, Associate Inc.<br><strong>Rating system:<\/strong> LEED v4 BD+C: WDC<br><strong>Gross floor area:<\/strong> 339,960 GSF<br><strong>Project description:<\/strong> Warehouse: Nonrefrigerated Distribution\/Shipping<br><strong>Certification:&nbsp;<\/strong>Certified &#8211; November 2022<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-6.png\"><img loading=\"lazy\" decoding=\"async\" width=\"974\" height=\"194\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-6.png\" alt=\"\" class=\"wp-image-1678\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-6.png 974w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-6-300x60.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-6-768x153.png 768w\" sizes=\"(max-width: 974px) 100vw, 974px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Courtesy of Hofmann Associates, Inc.<\/sup><\/figcaption><\/figure>\n\n\n\n<p>Climatic Design, LLC (CDL) has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for the Pompeian TPA Warehouse. Based on the final simulation results, the proposed design not only meets Minimum Energy Performance requirement but also qualifies for additional LEED points. Simulation results of the final energy models as shown in the Total energy usage table of the Performance Output tab of the Minimum Energy Performance Calculator, indicates the proposed design is 49.7% more energy cost efficient than the ASHRAE 90.1-2010 reference model. In the Design Final Review the project was awarded seventeen (17) points for Optimize Energy Performance credit (EA903).<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-7.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"336\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-7.png\" alt=\"\" class=\"wp-image-1680\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-7.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-7-300x103.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-7-768x265.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model with the original \u201cAs Is\u201d orientation, South West view<\/sup><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-25.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"452\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-25.png\" alt=\"\" class=\"wp-image-1459\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-25.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-25-300x139.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-25-768x356.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model, demonstrating the Interior Zones (Offices) North East vie<\/sup>w<\/figcaption><\/figure>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-26.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"379\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-26.png\" alt=\"\" class=\"wp-image-1460\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-26.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-26-300x117.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-26-768x299.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model demonstrating different glazing types, North West view<\/sup><\/figcaption><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-8.png\"><img loading=\"lazy\" decoding=\"async\" width=\"895\" height=\"251\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-8.png\" alt=\"\" class=\"wp-image-1681\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-8.png 895w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-8-300x84.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-8-768x215.png 768w\" sizes=\"(max-width: 895px) 100vw, 895px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model demonstrating different construction types, South East view<\/sup><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-9.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"181\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-9.png\" alt=\"\" class=\"wp-image-1682\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-9.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-9-300x56.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-9-768x143.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Source: Performance Output tab of the Minimum Energy Performance Calculator \u2013 LEED-Online<\/sup><\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-27.png\"><img loading=\"lazy\" decoding=\"async\" width=\"962\" height=\"1024\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-27-962x1024.png\" alt=\"\" class=\"wp-image-1461\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-27-962x1024.png 962w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-27-282x300.png 282w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-27-768x818.png 768w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-27.png 975w\" sizes=\"(max-width: 962px) 100vw, 962px\" \/><\/a><\/figure><\/div>","protected":false},"excerpt":{"rendered":"<p>Project Location:&nbsp;2100 Sparrows Point Road, Edgemere, MarylandOwner:&nbsp;Tradepoint Atlantic LLCArchitectural Firm:&nbsp;Hofmann, Associate Inc.Rating system: LEED v4 BD+C: WDCGross floor area: 339,960 GSFProject description: Warehouse: Nonrefrigerated Distribution\/ShippingCertification:&nbsp;Certified &#8211; November 2022 Climatic Design, LLC (CDL) has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for the Pompeian [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1458","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1458"}],"collection":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1458"}],"version-history":[{"count":3,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1458\/revisions"}],"predecessor-version":[{"id":1683,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1458\/revisions\/1683"}],"wp:attachment":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1458"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}