{"id":1472,"date":"2024-10-08T16:31:31","date_gmt":"2024-10-08T21:31:31","guid":{"rendered":"http:\/\/climaticdesign.net\/?page_id=1472"},"modified":"2024-11-07T14:40:33","modified_gmt":"2024-11-07T19:40:33","slug":"csms-surface-equipment-maintenance-facility","status":"publish","type":"page","link":"https:\/\/climaticdesign.net\/?page_id=1472","title":{"rendered":"CSMS Surface Equipment Maintenance Facility\u00a0"},"content":{"rendered":"\n<p><strong>Project Location:&nbsp;<\/strong> 301 Old bay lane, Havre de Grace, Maryland<br><strong>Owner\/Client:&nbsp;<\/strong> Maryland Military Department<br><strong>Architectural Firm:&nbsp; <\/strong>Penza+Bailey<strong> <\/strong>Architects<br><strong>Rating system:&nbsp;<\/strong> LEED v4 BD+C: NC<br><strong>Gross floor area:<\/strong> 42,400 sq ft<br><strong>Anticipated end date<\/strong>: 08 Sep 2020<br><strong>Project type:<\/strong>&nbsp; Service: Repair Shop<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-58.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"369\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-58.png\" alt=\"\" class=\"wp-image-1799\" style=\"width:840px;height:auto\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-58.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-58-300x114.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-58-768x291.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Courtesy of Penza+Bailey Architects<\/sup><\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p>Climatic Design LLC has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for the Surface Equipment Maintenance Facility (SEMF). Multiple Energy Conservation Measures (ECMs) were modeled. Simulation results of the final energy models, as demonstrated in total energy usage table, indicate the proposed design is 28.8% more energy cost efficient than the ASHRAE 90.1-2010 reference model. Upon the approval by GBCI, the project would achieve 11 points from the Optimize Energy Performance credit.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-33.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"427\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-33.png\" alt=\"\" class=\"wp-image-1473\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-33.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-33-300x131.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-33-768x336.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\">Rendering of the Baseline Reference Model with as is Orientation, South East view<\/figcaption><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-34.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"386\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-34.png\" alt=\"\" class=\"wp-image-1474\" style=\"width:841px;height:auto\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-34.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-34-300x119.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-34-768x304.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\">Rendering of the Baseline Reference Model demonstrating different fenestration types, North West view<\/figcaption><\/figure><\/div>\n\n\n<p> <\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-35.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"178\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-35.png\" alt=\"\" class=\"wp-image-1475\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-35.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-35-300x55.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-35-768x140.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\">Source: Performance Output tab of the Minimum Energy Performance Calculator \u2013 LEED-Online<\/figcaption><\/figure><\/div>","protected":false},"excerpt":{"rendered":"<p>Project Location:&nbsp; 301 Old bay lane, Havre de Grace, MarylandOwner\/Client:&nbsp; Maryland Military DepartmentArchitectural Firm:&nbsp; Penza+Bailey ArchitectsRating system:&nbsp; LEED v4 BD+C: NCGross floor area: 42,400 sq ftAnticipated end date: 08 Sep 2020Project type:&nbsp; Service: Repair Shop Climatic Design LLC has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1472","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1472"}],"collection":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1472"}],"version-history":[{"count":4,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1472\/revisions"}],"predecessor-version":[{"id":1800,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1472\/revisions\/1800"}],"wp:attachment":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1472"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}