{"id":1479,"date":"2024-10-08T16:45:51","date_gmt":"2024-10-08T21:45:51","guid":{"rendered":"http:\/\/climaticdesign.net\/?page_id=1479"},"modified":"2024-11-07T14:34:18","modified_gmt":"2024-11-07T19:34:18","slug":"csms-auto-maintenance-facility","status":"publish","type":"page","link":"https:\/\/climaticdesign.net\/?page_id=1479","title":{"rendered":"CSMS Auto Maintenance Facility"},"content":{"rendered":"\n<p><strong>Project Location:&nbsp;<\/strong> 301 Old bay lane, Havre de Grace, Maryland<br><strong>Owner:&nbsp;<\/strong>Maryland Military Department<br><strong>Architectural Firm:&nbsp;<\/strong>Penza+Bailey<strong> <\/strong>Architects<br><strong>Rating system:&nbsp;<\/strong>LEED v4 BD+C: NC<br><strong>Gross floor area:<\/strong> 19,881 sq ft<br><strong>Anticipated end date<\/strong>: 08 Sep 2020<br><strong>Project type:<\/strong>&nbsp;Service: Repair Shop<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-57.png\"><img loading=\"lazy\" decoding=\"async\" width=\"950\" height=\"617\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-57.png\" alt=\"\" class=\"wp-image-1796\" style=\"width:562px;height:auto\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-57.png 950w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-57-300x195.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-57-768x499.png 768w\" sizes=\"(max-width: 950px) 100vw, 950px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Courtesy of Penza+Bailey<strong> <\/strong>Architects<\/sup><\/figcaption><\/figure>\n\n\n\n<p>Climatic Design LLC has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for the Auto Maintenance Facility (AMF). Multiple Energy Conservation Measures (ECMs) were modeled. Based on the simulation results of the final energy models, annual energy costs of the proposed design is 32.9% lower than the ASHRAE 90.1-2010 reference model. This indicates the project is not only meets the Minimum Energy Performance requirement but also qualifies for additional LEED v4 NC points. Upon the approval by GBCI, the project would achieve 13 points from the Optimize Energy Performance credit.<\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-36.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"370\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-36.png\" alt=\"\" class=\"wp-image-1480\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-36.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-36-300x114.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-36-768x291.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model with as is Orientation, South West view<\/sup><br>\u00a0<\/figcaption><\/figure><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-37.png\"><img loading=\"lazy\" decoding=\"async\" width=\"906\" height=\"360\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-37.png\" alt=\"\" class=\"wp-image-1481\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-37.png 906w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-37-300x119.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-37-768x305.png 768w\" sizes=\"(max-width: 906px) 100vw, 906px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Proposed Design Model demonstrating different fenestration types, South West view<\/sup><\/figcaption><\/figure><\/div>\n\n\n<p> <\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-38.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"178\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-38.png\" alt=\"\" class=\"wp-image-1482\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-38.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-38-300x55.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-38-768x140.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Source: Performance Output tab of the Minimum Energy Performance Calculator \u2013 LEED-Online<\/sup><\/figcaption><\/figure><\/div>\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Project Location:&nbsp; 301 Old bay lane, Havre de Grace, MarylandOwner:&nbsp;Maryland Military DepartmentArchitectural Firm:&nbsp;Penza+Bailey ArchitectsRating system:&nbsp;LEED v4 BD+C: NCGross floor area: 19,881 sq ftAnticipated end date: 08 Sep 2020Project type:&nbsp;Service: Repair Shop Climatic Design LLC has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1479","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1479"}],"collection":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1479"}],"version-history":[{"count":4,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1479\/revisions"}],"predecessor-version":[{"id":1798,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1479\/revisions\/1798"}],"wp:attachment":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1479"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}