{"id":1484,"date":"2024-10-08T17:20:05","date_gmt":"2024-10-08T22:20:05","guid":{"rendered":"http:\/\/climaticdesign.net\/?page_id=1484"},"modified":"2024-11-08T10:55:12","modified_gmt":"2024-11-08T15:55:12","slug":"turf-valley-office-building-c","status":"publish","type":"page","link":"https:\/\/climaticdesign.net\/?page_id=1484","title":{"rendered":"Turf Valley Office Building C"},"content":{"rendered":"\n<p><strong>Project Location:\u00a0<\/strong>11115 Resort Road, Ellicott City, Maryland<br><strong>Owner\/Client:\u00a0<\/strong>TVTS Office LLC<br><strong>Architectural Firm:\u00a0<\/strong>Hofmann Associates Inc.<strong><br>Rating system:\u00a0<\/strong>LEED v4 BD+C: CS<br><strong>Gross floor area:<\/strong> 56,764 sq ft<br><strong>Anticipated end date<\/strong>: 27 May 2020<br><strong>Project type:<\/strong>\u00a0Office: Administrative\/Professional<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-39.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"558\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-39.png\" alt=\"\" class=\"wp-image-1485\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-39.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-39-300x172.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-39-768x440.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Turf Valley Office Building C, Schematic Design, courtesy of Hofmann Associates Inc.<\/sup><\/figcaption><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p>Climatic Design LLC performed a whole-building energy model simulation, a comprehensive energy analysis and an assessment of the building systems and configuration for the Turf Valley Building C. Simulation results of the final energy models demonstrated that the proposed design is 20.3% more energy cost efficient than the ASHRAE 90.1-2010 reference model. In the Design Final Review the project was awarded nine (9) points for Optimize Energy Performance credit.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-40.png\"><img loading=\"lazy\" decoding=\"async\" width=\"766\" height=\"330\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-40.png\" alt=\"\" class=\"wp-image-1486\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-40.png 766w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-40-300x129.png 300w\" sizes=\"(max-width: 766px) 100vw, 766px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model, South West view<\/sup><\/figcaption><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-41.png\"><img loading=\"lazy\" decoding=\"async\" width=\"769\" height=\"336\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-41.png\" alt=\"\" class=\"wp-image-1487\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-41.png 769w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-41-300x131.png 300w\" sizes=\"(max-width: 769px) 100vw, 769px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Proposed Design Model with different Glazing, North East view<\/sup><\/figcaption><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p>Simulation results of the final energy models demonstrated that the proposed design is 20.3% more energy cost efficient than the ASHRAE 90.1-2010 reference model. In the Design Final Review the project was awarded twenty five (9) points for Optimize Energy Performance credit.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-42.png\"><img loading=\"lazy\" decoding=\"async\" width=\"848\" height=\"1024\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-42-848x1024.png\" alt=\"\" class=\"wp-image-1488\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-42-848x1024.png 848w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-42-248x300.png 248w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-42-768x928.png 768w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-42.png 975w\" sizes=\"(max-width: 848px) 100vw, 848px\" \/><\/a><\/figure><\/div>","protected":false},"excerpt":{"rendered":"<p>Project Location:\u00a011115 Resort Road, Ellicott City, MarylandOwner\/Client:\u00a0TVTS Office LLCArchitectural Firm:\u00a0Hofmann Associates Inc.Rating system:\u00a0LEED v4 BD+C: CSGross floor area: 56,764 sq ftAnticipated end date: 27 May 2020Project type:\u00a0Office: Administrative\/Professional Climatic Design LLC performed a whole-building energy model simulation, a comprehensive energy analysis and an assessment of the building systems and configuration for the Turf Valley Building [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1484","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1484"}],"collection":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1484"}],"version-history":[{"count":4,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1484\/revisions"}],"predecessor-version":[{"id":1822,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1484\/revisions\/1822"}],"wp:attachment":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1484"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}