{"id":1508,"date":"2024-10-09T08:50:14","date_gmt":"2024-10-09T13:50:14","guid":{"rendered":"http:\/\/climaticdesign.net\/?page_id=1508"},"modified":"2024-11-07T17:26:42","modified_gmt":"2024-11-07T22:26:42","slug":"johnson-global-academy","status":"publish","type":"page","link":"https:\/\/climaticdesign.net\/?page_id=1508","title":{"rendered":"Katherine Johnson Global Academy"},"content":{"rendered":"\n<p><strong>Project Location:&nbsp;<\/strong>1100 Whitmore Avenue, Baltimore, Maryland<br><strong>Owner\/Client:&nbsp;<\/strong>Maryland Stadium Authority<br><strong>Architectural Firm:&nbsp;<\/strong>JRS Architects<strong><br>Rating system:&nbsp;<\/strong>LEED FOR SCHOOLS v2009<br><strong>Gross floor area:<\/strong> 122,525 sq ft<br><strong>Project type:<\/strong> Core Learning Space: K-12 Elementary\/Middle School<br><strong>Certification:&nbsp;<\/strong>Gold \u2013 July 2022<\/p>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-60.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"544\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-60.png\" alt=\"\" class=\"wp-image-1807\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-60.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-60-300x167.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/11\/image-60-768x429.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Courtesy of JRS Architects<\/sup><\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p>Climatic Design LLC has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for the Calverton Elementary Middle School. With the execution of the recommended ECMs, the proposed design complied with the Minimum Energy Performance requirement and achieved additional LEED points. As exhibited in the LEED Scorecard, the project was 41.2% more energy cost efficient than the ASHRAE 90.1-2007 reference model. This equates to fifteen (15) LEED-NC 2009 EAc1 points.<\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-55.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"482\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-55.png\" alt=\"\" class=\"wp-image-1509\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-55.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-55-300x148.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-55-768x380.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model with the original \u201cAs Is\u201d orientation, South West view<\/sup><\/figcaption><\/figure><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-56.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"414\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-56.png\" alt=\"\" class=\"wp-image-1510\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-56.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-56-300x127.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-56-768x326.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Baseline Reference Model demonstrating thermal zones of the First Floor<\/sup><\/figcaption><\/figure><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-57.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"495\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-57.png\" alt=\"\" class=\"wp-image-1511\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-57.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-57-300x152.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-57-768x390.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\"><sup>Rendering of the Proposed Model, North West view<\/sup><\/figcaption><\/figure><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-58.png\"><img loading=\"lazy\" decoding=\"async\" width=\"932\" height=\"1024\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-58-932x1024.png\" alt=\"\" class=\"wp-image-1512\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-58-932x1024.png 932w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-58-273x300.png 273w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-58-768x844.png 768w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-58.png 975w\" sizes=\"(max-width: 932px) 100vw, 932px\" \/><\/a><\/figure><\/div>","protected":false},"excerpt":{"rendered":"<p>Project Location:&nbsp;1100 Whitmore Avenue, Baltimore, MarylandOwner\/Client:&nbsp;Maryland Stadium AuthorityArchitectural Firm:&nbsp;JRS ArchitectsRating system:&nbsp;LEED FOR SCHOOLS v2009Gross floor area: 122,525 sq ftProject type: Core Learning Space: K-12 Elementary\/Middle SchoolCertification:&nbsp;Gold \u2013 July 2022 Climatic Design LLC has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for the Calverton [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1508","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1508"}],"collection":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1508"}],"version-history":[{"count":4,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1508\/revisions"}],"predecessor-version":[{"id":1809,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1508\/revisions\/1809"}],"wp:attachment":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1508"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}