{"id":1585,"date":"2024-10-30T16:00:19","date_gmt":"2024-10-30T21:00:19","guid":{"rendered":"http:\/\/climaticdesign.net\/?page_id=1585"},"modified":"2024-10-30T16:00:19","modified_gmt":"2024-10-30T21:00:19","slug":"22-040-sunbelt","status":"publish","type":"page","link":"https:\/\/climaticdesign.net\/?page_id=1585","title":{"rendered":"22-040 Sunbelt"},"content":{"rendered":"\n<p>Project Location:\u00a0 Laurel. Maryland<br>Architectural Firm:\u00a0 Hofmann Associates, Inc.<br>Rating system:\u00a0 IECC 2021\/ASHRAE 90.1-2019 Compliance<br>Gross floor area: 10,520 GSF <br>Project type: Vehicular Maintenance Facility<\/p>\n\n\n\n<p>Climatic Design LLC has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for the 22-040 Sunbelt (SUNBELT), which complies with section 407.2 of the 2021 IECC. Multiple Energy Conservation Measures (ECMs) that were implemented in the proposed design were modeled to demonstrate SUNBELT compliance with the Code requirements. Based on the simulation results, annual energy usage of the proposed design is 379.6 MBTU lower than ASHRAE 90.1-2019 Appendix G Reference model, which means annual energy usage of the proposed design is 36% lower than the standard baseline. In addition, calculated Performance Cost Index (PCI) and Performance Cost Index target (PCIt) per ASHRAE 90.1-2019 Section 4.2.1.1 demonstrated that the proposed design complies with 2021 IECC and ASHRAE 90.1-2019 requirements; PCI (0.50) is less than PCIt (0.59).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-71.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"460\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-71.png\" alt=\"\" class=\"wp-image-1586\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-71.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-71-300x142.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-71-768x362.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\">Rendering of the Baseline Reference Model with as is Orientation, South East view<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-72.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"490\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-72.png\" alt=\"\" class=\"wp-image-1587\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-72.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-72-300x151.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-72-768x386.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\">Rendering of the Baseline Reference Model with as is Orientation, North West view<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-73.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"714\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-73.png\" alt=\"\" class=\"wp-image-1588\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-73.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-73-300x220.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-73-768x562.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><figcaption class=\"wp-element-caption\">Annual Energy Consumption by Endues \u2013 Proposed Design vs Baseline Case<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-74.png\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"514\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-74.png\" alt=\"\" class=\"wp-image-1589\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-74.png 975w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-74-300x158.png 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/image-74-768x405.png 768w\" sizes=\"(max-width: 975px) 100vw, 975px\" \/><\/a><\/figure>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Project Location:\u00a0 Laurel. MarylandArchitectural Firm:\u00a0 Hofmann Associates, Inc.Rating system:\u00a0 IECC 2021\/ASHRAE 90.1-2019 ComplianceGross floor area: 10,520 GSF Project type: Vehicular Maintenance Facility Climatic Design LLC has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for the 22-040 Sunbelt (SUNBELT), which complies with section 407.2 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1585","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1585"}],"collection":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1585"}],"version-history":[{"count":1,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1585\/revisions"}],"predecessor-version":[{"id":1590,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/1585\/revisions\/1590"}],"wp:attachment":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}