{"id":955,"date":"2015-06-23T13:15:00","date_gmt":"2015-06-23T18:15:00","guid":{"rendered":"http:\/\/climaticdesign.net\/?page_id=955"},"modified":"2024-11-07T14:14:00","modified_gmt":"2024-11-07T19:14:00","slug":"youth-detention-center","status":"publish","type":"page","link":"https:\/\/climaticdesign.net\/?page_id=955","title":{"rendered":"Youth Detention Center"},"content":{"rendered":"\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4>Youth Detention Center<\/h4>\n<p><strong>Project Location:\u00a0<\/strong>Baltimore, Maryland<br \/><strong style=\"line-height: 1.5em;\">Architecture Firm:\u00a0<\/strong><span style=\"line-height: 1.5em;\">PSA &#8211; Dewberry + Penza Bailey Architects, Baltimore, Maryland<br \/><\/span><strong style=\"line-height: 1.5em;\">Project description:\u00a0<\/strong><span style=\"line-height: 1.5em;\">A three-story structure with a total of 52,317 GSF<br \/><strong>LEED Rating:<\/strong> <a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2018\/06\/1000041747-LEED-Scorecard-e1528478902917.jpg\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"color: #000080;\"><em>Awarded LEED v3 Gold<\/em><\/span><\/a><br \/><strong>Certification Date<\/strong>: November 2017<\/span><\/p>\n<p><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/YDC-3D-Image.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-959\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/YDC-3D-Image.jpg\" alt=\"YDC-3D Image\" width=\"686\" height=\"412\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/YDC-3D-Image.jpg 754w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/YDC-3D-Image-300x180.jpg 300w\" sizes=\"(max-width: 686px) 100vw, 686px\" \/><\/a><br \/>Courtesy of PSA \u2013 Dewberry + Penza Bailey Architects<\/p>\n<p>&nbsp;<\/p>\n<p>CDL has performed a whole-building energy model simulation, a comprehensive energy analysis, and an assessment of the building systems and configuration for the BCDC Youth Detention Center (YDC) in Baltimore, Maryland. Multiple Energy Conservation Measures (ECMs) were modeled. With the execution of selected ECMs, The proposed design meets Minimum Energy Performance. The facility is 26.77% ($60,503\/yr) more efficient than the \u201cASHRAE 90.1-2007 Baseline\u201d facility. The project has been awarded 8 EAc1 credit points in LEED-Online.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Design_NE.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-960 aligncenter\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Design_NE.jpg\" alt=\"Design_NE\" width=\"688\" height=\"384\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Design_NE.jpg 1476w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Design_NE-300x167.jpg 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Design_NE-1024x572.jpg 1024w\" sizes=\"(max-width: 688px) 100vw, 688px\" \/><\/a><\/p>\n<p style=\"text-align: center;\">Rendering of Baseline Case with the original \u201cAs Is\u201d orientation<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Baseline-Walls_SW-View.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-961 aligncenter\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Baseline-Walls_SW-View.jpg\" alt=\"Baseline-Walls_SW View\" width=\"690\" height=\"318\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Baseline-Walls_SW-View.jpg 1525w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Baseline-Walls_SW-View-300x138.jpg 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Baseline-Walls_SW-View-1024x471.jpg 1024w\" sizes=\"(max-width: 690px) 100vw, 690px\" \/> <\/a>Rendering of Baseline Case showing construction types, South West view<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Baseline-Glazing_NW-View.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-962 aligncenter\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Baseline-Glazing_NW-View.jpg\" alt=\"Baseline-Glazing_NW View\" width=\"689\" height=\"326\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Baseline-Glazing_NW-View.jpg 1464w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Baseline-Glazing_NW-View-300x142.jpg 300w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2015\/06\/Baseline-Glazing_NW-View-1024x484.jpg 1024w\" sizes=\"(max-width: 689px) 100vw, 689px\" \/><\/a>Rendering of Baseline Case showing glazing types and skylights, North West view<\/p>\n<p>&nbsp;<\/p>\n<p>To make the project as energy efficient as possible, the project team implemented following<br \/>Energy Conservation Measures.<\/p>\n<p>1. The baseline building\u2019s roof insulation value is around R-16, the insulation value of the<br \/>existing part of the project is R-0.78. Selected roof systems for the project have assembly<br \/>U-value of 0.032 (R-30) and 0.037 (R-27).<\/p>\n<p>2. The insulation value of the baseline building\u2019s exterior walls is R-16 and this value for<br \/>exterior walls of the existing SUI building is R-1.72. Selected wall systems of new part of the<br \/>project have U-value of 0.053 (R-19) to U-0.066 (R-15). Assembly U-value of exterior walls<br \/>of the existing building in the proposed design is the same as the baseline case.<\/p>\n<p>3. The baseline building\u2019s window assembly U-value in the new building for storefront windows<br \/>is 0.5 and for all other windows is 0.55. This value for the existing part of the project is 0.85.<br \/>Assembly U-values of the glazing implemented in the project including the existing part but<br \/>excluding the security windows, as described in table 1-1 are much lower than the baseline<br \/>energy model (0.14 to 0.36).<\/p>\n<p>4. The baseline building\u2019s skylight assembly U-value is 1.17. Assembly U-value of the<br \/>skylights in the proposed design is 0.60.<\/p>\n<p>5. Per ASHRAE Standard 90.1-2007 the baseline building has no daylighting control,<br \/>but in the proposed design lights of all spaces with windows or\/and skylights are controlled<br \/>by daylight sensors. All the spaces within the project have, with 30% dimming.<\/p>\n<p>6. Using the ASHRAE Standard 90.1-2007 \u201cBuilding Area\u201d method for lighting power density,<br \/>calculated average internal lighting power density (LPD) of the baseline building is 1.05 Watt<br \/>per square feet (W\/sf). Calculated average internal LPD of the proposed design is 0.8 W\/sf,<br \/>which is more than 23% below the ASHRAE Standards.<\/p>\n<p>7. The proposed design HVAC systems, packaged single zone roof top units with furnace<br \/>heating, and heat recovery wheel are more energy efficient that the baseline building\u2019s HVAC systems.<\/p>\n<p>8. Decentralized electrical hot water systems of the proposed design are using<br \/>less energy than centralized baseline building hot water system.<\/p>\n<p><a href=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/YDC-Gpld-Certified.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1396\" src=\"http:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/YDC-Gpld-Certified.jpg\" alt=\"\" width=\"692\" height=\"760\" srcset=\"https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/YDC-Gpld-Certified.jpg 1042w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/YDC-Gpld-Certified-273x300.jpg 273w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/YDC-Gpld-Certified-932x1024.jpg 932w, https:\/\/climaticdesign.net\/wp-content\/uploads\/2024\/10\/YDC-Gpld-Certified-768x844.jpg 768w\" sizes=\"(max-width: 692px) 100vw, 692px\" \/><\/a><\/p>\n<p style=\"text-align: center;\">Climatic Design = Energy Savings + Protecting the Environment<br \/>Call<a href=\"http:\/\/climaticdesign.net\/?page_id=91\" target=\"_blank\" rel=\"noopener noreferrer\"><strong> CDL<\/strong><\/a>\u00a0to meet your energy savings<\/p>\n<p><a href=\"http:\/\/climaticdesign.net\/?page_id=32\" target=\"_self\" rel=\"noopener\">Return<br \/><\/a><a href=\"http:\/\/climaticdesign.net\/\" target=\"_self\" rel=\"noopener\">Home<\/a><\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Youth Detention Center Project Location:\u00a0Baltimore, MarylandArchitecture Firm:\u00a0PSA &#8211; Dewberry + Penza Bailey Architects, Baltimore, MarylandProject description:\u00a0A three-story structure with a total of 52,317 GSFLEED Rating: Awarded LEED v3 GoldCertification Date: November 2017 Courtesy of PSA \u2013 Dewberry + Penza Bailey Architects &nbsp; CDL has performed a whole-building energy model simulation, a comprehensive energy analysis, and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":32,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-955","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/955"}],"collection":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=955"}],"version-history":[{"count":18,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/955\/revisions"}],"predecessor-version":[{"id":1794,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/955\/revisions\/1794"}],"up":[{"embeddable":true,"href":"https:\/\/climaticdesign.net\/index.php?rest_route=\/wp\/v2\/pages\/32"}],"wp:attachment":[{"href":"https:\/\/climaticdesign.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=955"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}