Eastern Bus Division Redevelopment
Project Location: Baltimore, Maryland
Owner: Maryland Transit Administration
Architectural Firm: WRA, LLP
Rating system: LEED v4.1 BD+C: NC/ASHRAE 90.1-2016
Gross floor area: 75,000 GSF
Anticipated end date: May 2023
Project type: Transit
Certification: TBD
Climatic Design LLC (CDL) is working with the design team from the concept design phase to provide early analysis of energy systems of the project in order to identify synergies within the project design that can optimize energy performances. During the design phase CDL has performed a whole-building energy model simulation, a comprehensive energy analysis and an assessment of the building systems and configuration for the project. The simulation results demonstrate that by applying the recommended Energy Conservation Measures (ECM) to the proposed design the project meets Minimum Energy Performance requirement and qualifies for additional LEED points. ASHRAE 90.1-2016 requires calculating Performance Cost Index (PCI) and Performance Cost Index target (PCIt) per metrics of energy costs and Greenhouse Gas (GHG) emissions and demonstrating that the PCI is less than or equal to the PCIt. Based on the simulation results, calculated PCI per energy costs metric and GHG metric are less than the calculated PCIt; the percentage of improvement of the current proposed design beyond ASHRAE 90.1-2016 inclusion of on-site solar systems is 51.4% for energy cost and 52.2% for GHG emission, which yield to total of 17 points for Optimize Energy Performance under LEED v4.1 rating system.